How to replenish water in wall-hung boiler
As a common heating equipment in modern homes, wall-mounted boilers are inseparable from proper water pressure for their normal operation. Replenishing water is an important part of daily maintenance of wall-mounted boilers, but many users are not familiar with the operating steps and precautions. This article will introduce in detail the correct method of replenishing water in a wall-mounted boiler, and attach relevant data for reference.
1. Preparations before filling the wall-hung boiler with water

1. Make sure the wall-hung boiler is in shutdown state and avoid operating at high temperatures.
2. Check whether there is any water leakage in the system.
3. Prepare the appropriate tools (such as a refill key or screwdriver).
| Check items | normal range | Exception handling |
|---|---|---|
| water pressure gauge reading | 1.0-1.5bar | If it is lower than 1.0, you need to replenish water. |
| Pipe connection | No leakage | If water leakage is found, report it for repair |
2. Detailed explanation of water replenishment steps for wall-hung boilers
1.Find the refill valve: Usually located at the bottom of the wall-mounted boiler, marked with the words "replenish water".
2.Open the valve slowly: Just turn it 1/4 turn counterclockwise.
3.Observe the pressure gauge: Stop when the pointer reaches 1.2-1.5bar.
4.close valve: Turn clockwise to fully close.
5.Check system: Start the wall-hung boiler and observe whether it is operating normally.
| Operation steps | time requirement | Things to note |
|---|---|---|
| Open the water replenishment valve | about 30 seconds | Move slowly |
| hydration process | 2-3 minutes | Watch the pressure gauge closely |
3. Precautions after replenishing water
1. After replenishing water, wait 10 minutes before starting the wall-hung boiler.
2. The pressure may drop after replenishing water for the first time, which is normal.
3. If the pressure continues to drop, there may be a water leakage problem.
4. Pay special attention to anti-freezing measures when replenishing water in winter.
| phenomenon | Possible reasons | Solution |
|---|---|---|
| Rapid pressure drop | System leaks | Contact a professional |
| Unstable pressure | There is air in the pipe | Perform exhaust operation |
4. Frequently Asked Questions
Q: How often does the wall-mounted boiler need to be replenished with water?
A: Under normal circumstances, inspection should be done once every 3-6 months, depending on usage.
Q: What should I do if the water flow makes a loud sound when replenishing water?
A: This may be because there is air in the system. It is recommended to exhaust it first and then replenish the water.
Q: What should I do if the water replenishment valve cannot be opened?
A: Do not force the operation and contact professional maintenance personnel.
| Question type | frequency of occurrence | Urgency |
|---|---|---|
| Water replenishment valve failure | 5% | in |
| abnormal pressure | 15% | high |
5. Professional advice
1. It is recommended to check the water pressure every quarter.
2. When not in use for a long time, the system water should be drained.
3. Wall-hung boilers of different brands may have slight differences, please refer to the instructions.
4. If you encounter complex problems, you should contact professional maintenance personnel in time.
Through the above detailed water replenishment guide, we hope to help you properly maintain your wall-mounted boiler and ensure the heating effect in winter. Remember, regular inspections and proper hydration are keys to extending the life of your boiler.